Login Failed;0xC0202009; Cannot Acquire Connection From Connection Manager

Dec 17, 2007

hi all,
i got the error, when i run my package after deploy into the server machine;
i can able to run that package in my local machine, if i deploy it to the server or some remote machine, its not running, and rises error messages, that says cant accquire connection from the connection manager;

the problem might be with the login name and password; i could not see any password in any of my config file, or connection manager while running the package.
how to resolve this problem?? please help me!

View 6 Replies


ADVERTISEMENT

The AcquireConnection Method Call To The Connection Manager Excel Connection Manager Failed With Error Code 0xC0202009

Mar 24, 2008

I am using SSIS 2005 on Windows 2003 server. Using Excel Source to dump the data for staging database.
I am getting following error while I execute it through BI studio's execute button.

Please help.

- Sachin

View 2 Replies View Related

The AcquireConnection Method Call To The Connection Manager Excel Connection Manager Failed With Error Code 0xC0202009

Mar 11, 2008

I have deployed my packages into Sql Server and I am using Configuration File. As my Data Source is Excel, I have changed the connection string during deployment with Server Path. But I am getting the following errors. Actually the File Exist in Path. May I know What is cause of the issue? Do I need to give any permission to execute the package.



SSIS Error Code DTS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER. The AcquireConnection method call to the connection manager "Excel Connection Manager" failed with error code 0xC0202009. There may be error messages posted before this with more information on why the AcquireConnection method call failed.



component "Excel Source Service Contract Upload" (1) failed validation and returned error code 0xC020801C.

One or more component failed validation.



There were errors during task validation.

DTS_E_OLEDBERROR, Error Code: 0x80004005 Source: "MS JET DB Engine" Description : Path is not valid


View 27 Replies View Related

Error: The AcquireConnection Method Call To The Connection Manager Excel Connection Manager Failed With Error Code 0xC0202009.

Dec 27, 2007

Hi,

I am working on SQL Server 2005 (x64) with Windows Server 2003 (x64) operating system. I am having a major issue in SSIS. Here is the detailed explanation of the issue :

I have an EXCEL file in 2003 / 2007 version. It contains some data. I want to import the data using SSIS into SQL Server 2005 (x64) database table. I have taken "EXCEL FILE SOURCE" and "SQL Server DESTINATION". It was failed on importing data. Surprisingly it works fine in SQL Server 2005 (x32). Can you please explain why it is NOT woking on (x64) ?

Here is the error code i am getting:

[Excel Source [1]] Error: The AcquireConnection method call to the connection manager "Excel Connection Manager" failed with error code 0xC0202009.

Appreciate your time and patience !!

Thanks

View 3 Replies View Related

Help! AcquireConnection Method Call To The Connection Manager Failed With Error Code 0xC0202009

Feb 17, 2006

The package runs fine if I run it by itself. Unfortunately we want to call it from another package and when we do so it fails everytime with the following error; "AcquireConnection method call to the connection manager "BPCSF" failed with error code 0xC0202009." This package is calling an AS400 and pulling data from it into a staging environment. The task that is failing is 4th task on the list and is the 3rd task to call the AS400 environment. If I need to provide more information I would be happy to do so. Any help would be greatly appreciated. Thanks!

-Krusty

View 1 Replies View Related

The AcquireConnection Method Call To The Connection Manager Myconnection Failed With Error Code 0xC0202009.

Oct 9, 2007

I can run this package in Studio and it works fine, but when I run it from SQL Server Agent, it throws this error. Does anybody know what would cause this problem. This appears to occur during validation for the package because none of the data flow steps run. The connection being used is the same connection used in all of the data flows. If validation is done in order, then prior steps using the same connection are passing validation.

Thanks,

Steve

View 5 Replies View Related

The AcquireConnection Method Call To The Connection Manager Server.Northwind Failed With Error Code 0xC0202009;

Aug 20, 2007

Error at Text Inbound Task [SQL Server Destination [9]]: The AcquireConnection method call to the connection manager "Server.Northwind" failed with error code 0xC0202009.
Error at Text Inbound Task [DTS.Pipeline]: component "SQL Server Destination" (9) failed validation and returned error code 0xC020801C.

Please keep me posted with alternate work around(s) /solution(s).

View 1 Replies View Related

Cannot Acquire A Managed Connection From The Run-time Connection Manager

Jul 26, 2006

How would one go about using an ODBC connection with SSIS. I'm trying to ETL some Sybase ASE data, but I get the error when I try it:

"cannot acquire a managed connection from the run-time connection manager"



This wasn't any help:

http://forums.microsoft.com/MSDN/ShowPost.aspx?PostID=169777&SiteID=1



View 1 Replies View Related

Maint Plan - Failed To Acquire Connection Local Server Connection

Feb 15, 2008

I created a single step plan that does integrity checks. It fails with the error below. I created a new connection using our clusters virtual sql name.


Executed as user: ACCTCOMsqlagent. ...n 9.00.3042.00 for 64-bit Copyright (C) Microsoft Corp 1984-2005. All rights reserved. Started: 1:10:06 PM Error: 2008-02-15 13:10:49.02 Code: 0xC00291EC Source: {0CF32F3D-A8D1-492A-9C0F-AD4E0FC67D14} Execute SQL Task Description: Failed to acquire connection "Local server connection". Connection may not be configured correctly or you may not have the right permissions on this connection. End Error Warning: 2008-02-15 13:10:49.02 Code: 0x80019002 Source: OnPreExecute Description: SSIS Warning Code DTS_W_MAXIMUMERRORCOUNTREACHED. The Execution method succeeded, but the number of errors raised (1) reached the maximum allowed (1); resulting in failure. This occurs when the number of errors reaches the number specified in MaximumErrorCount. Change the MaximumErrorCount or fix the errors. End Warning Error: 2008-02-15 13:11:31.26 Code: 0xC0024104 Source: Check Database Integrity Ta... The package execution fa... The step failed.

The agent and db are running under domain accounts and the job is owned by sa.

Thanks for your help.


View 13 Replies View Related

OlE DB Source - Cannot Acquire Connection From Connection Manager

Jul 13, 2007

My source files are in C:Process folder. File names are in the format proc*.csv

I am using foreach loop container to iterate over the files in folder "C:Process"

I have a user variable "filename"



The order of my tasks

ForEach - Data Flow task - File System Task



In Data Flow task, I have ole db source which should take the dynamic filename from user variable "filename". whats happening is when i give fixed filename, without foreach loop container the package is working fine.

with dynamic filename, I am not able to run the package because of ole db source Error - cannot aquire connection from connection manager.



Thanks for u'r help.

View 9 Replies View Related

The AcquireConnection Method Call To The Connection Manager 'Blah Blah' Failed With Error Code 0xC0202009.

Apr 27, 2007

Hello everyone,



I am struggling with this error and it's starting to get to me!



I have setup a simple project with just a data flow task. In this task, it retrieves a simple record "Select * From Table1 WhereId=1". The connection is an OLE Db connection using Advantage Oledb Provider (a provider for accessing dBase). It is accessing a Novell network drive. I have setup the package to both "EncryptSensitiveWithPassword" and "DontSaveSensitive". Both times i have received this error.



The funny thing is, when I set the package to "EncryptSensitiveWithPassword" and I setup a job to run the package, it never asks me for the password even though I set one up! I have a previous package (few months ago I made) that accessed the same database on the same Network drive and it works! It also asks me for a password when I try to modify or run the package (b/c I set it to "EncryptW/Password").



Can anyone give any light into this problem?



Thansk for all your support,



Adrian



View 1 Replies View Related

Failed To Acquire Connection Tempdb

Jan 22, 2006

Hi, I have an SSIS project, has a connection to tempdb (local sql2k5 server), 3 tasks, creating a table, populating the table, then deleting the table. of course when I test the connection i GET TEST Succesfull (I amusing sa ...)

Whenever I run the package, all tasks become red colored indicating, I get the following error :
---------------------------------------------------------------------------------------------------------------------------
[Execute SQL Task] Error: Failed to acquire connection "tempdb".
connection may not be configured correctly or you may not have the right permissions on this connection.vance
----------------------------------------------------------------------------------------------------------------------------
Any help would be appreciated. Thanks in advance

View 1 Replies View Related

Failed To Acquire Connection / The AcquireConnection Method Failed

Nov 11, 2005

I am running the Sept CTP.  I have created a SSIS package that pulls data from a text file and inserts into a database.  When I run the package on the DB server it runs fine.  I have moved the package the the web server (we are attempting to kick off the package from a web site) and we get connections errors. We are running the package using dtexec from the command line.

View 7 Replies View Related

SQL Server 2008 :: Failed To Acquire Connection (Local Server Connection)

May 5, 2014

Occasionally I'm seeing the following error when tranlog or full backup maintenance plan is executing.

Failed-1073573396) Failed to acquire connection "Local server connection". Connection may not be configured correctly or you may not have the right permissions on this connection.

What is strange is that it goes away without any action from myself. We have a tranlog backup that is scheduled every hour. I had this error happen once in the middle of the night. It looks like the job was running fine because almost all the backups are there. I've searched and not found a resolution to this error. I checked the event log and don't see any issues and even tried rebuilding the maintenance plans.

View 7 Replies View Related

Failed OLEDB Connection: Cannot Aquire Connection From Connection Manager

Feb 6, 2008

I have a package that uses a for loop to iterate through an unknown amount of excel files and pull their data into a table. However, there will be cases when the file is corrupted or has some sort of problem so that either the transformation will fail or the excel data source will fail with an oledb connection error.
Could anyone suggest a clean way to trap these errors? Specifically, the "Cannot Aquire Connection from Connection Manager", which is the excel connection.

Thanks,

John T

View 3 Replies View Related

Sql Connection Failed Because Of Connection Failure Login Failed For User 'SW8/Guest

May 16, 2007

Sir i am trying to connect sql from my LAN to my networked computers but whenever i tried to register it through Enterprise manager i get following "SQL Server registration failed because of the conection failure displayed below.Do you wish to Register anyway? Login failed for user 'SW17/Guest'

where SW17/ is my another computer name...
i have checked tcp and named pipes
and confirm username for sql authentication too
please help me as i being late submit my project

View 3 Replies View Related

Failed To Acquire Connection Message On SSIS Packs From Within Integration Services

Aug 20, 2007

Hi all,

I am trying to run eight SSIS packs from within Integration Services > Stored Packages > File System and seem to get an error like the following on all of them:

"Failed to acquire connection "MyConnection". Connection may not be configured correctly or you may not have the right permissions on this connection.

I can run the packages without error from within VS and from within that location in Integration Services on the machine containing the the databases, but when I attempt to run them remotely I get that error. I am attempting this with full admin access on both machines, but the purpose behind these packages is for our developers to run them on individual databases whenever they need to. So I'm concerned that I may run into further access errors after this, but so far I can't find a reason why this connection would fail. Any ideas?

If I can supply more information please let me know. Thanks in advance for any information!

View 6 Replies View Related

The AcquireConnection Method Call To The Connection Manager &&<Connection Name&&> Failed With Error Code 0xC020200

Feb 14, 2008

Hi All,
I am getting the following error if I am using the package "Transaction Option=Required" while running through Sql Job:
The AcquireConnection method call to the connection manager "<connection name>" failed with error code 0xC0202009.

while I running the SSIS package on BI environment, I am getting the following error:
[Connection manager "<connection name>"] Error: The SSIS Runtime has failed to enlist the OLE DB connection in a distributed transaction with error 0x8004D00A "Unable to enlist in the transaction.".

I know the alternative solution is to make the "Transaction Option=Supported", but in my case I have run the whole flow in a single transaction. I came to know that this has been fixed in the service pack1(ref. to http://support.microsoft.com/kb/914375). FYI.. some time it was running successful.

I have taken all the necessary step to run the SSIS package in a distributed transaction(like the steps for MSDTC) and also created the package flow in a sequence.

I was going through the link - http://forums.microsoft.com/MSDN/ShowPost.aspx?PostID=160340&SiteID=1 but all those didn't solve my problem.

If anyone can help me it will be great. or it is a bug in SSIS?

Thanks.
Jena

View 5 Replies View Related

Implementing Transaction In SSIS Package - [Execute SQL Task] Error: Failed To Acquire Connection &&<ConnectionName&&>.

Jun 30, 2006

I have a simple SSIS package with three "Execute SQL Tasks". I am using ADO.Net Connection to execute SPs on a DB server.

When I execute this package It works fine. So far so good.

Now, I need to implement transation on this package. And problem starts now onwards. When I try to execute package after setting TransationOption = Required for the Sequence container which contains all the tasks, I get following error.

[Execute SQL Task] Error: Failed to acquire connection "NYCDB0008.Export". Connection may not be configured correctly or you may not have the right permissions on this connection.

"NYCDB0008.Export" is the name of the ADO.Net connection. I have been hunting for any solution but all in vain. I have tried changing all DTC settings on the dev as well as Database server.

Please respond if anyone has any solution.

Thanks!

Anand

View 24 Replies View Related

Login Failed For Trusted Connection Login Failed For User 'NT AUTHORITYANONYMOUS LOGON'

Mar 13, 2007

We have a SQL 2000 Active/Passive cluster running on Windows 2000. On one node, everything logs in fine (second node is powered off). I can use local authentication fine in OSQL (-E) and even see my connection in SQLEM current activity as [DomainUser] for the NT account which I am logged in as. Then I bring the second node online and initiate a failover. SQL Server starts but Cluster Admin cannot connect and starts throwing this Anonymous Logon error. I open a command prompt and try the same OSQL (-E) local login and sure enough it is also giving the Anonymous Logon connection user. I do not understand why the failover to a second node is causing the Trusted Connection Local authentication to switch to Anonymous instead of the [DomainUser] which I am using. Any help is appreciated. John.

View 1 Replies View Related

Failed To Acquire Connection When Running A Package From Within Another Package.

Apr 26, 2006

I am receiving an error on my master package that executes a number of other packages. The individual packages work fine when executed by themselves. However, I am getting the following error when I attempt to execute it from another package:

Error: Failed to acquire connection "conneciton". Connection may not be configured correctly or you may not have the right permissions on this connection.

Thanks in advance for your help.



View 1 Replies View Related

Entreprise Manager Error Message: [Microsoft][ODBC SQL ServerDriver][SQL Server]Login Failed For User '#####'. The User Is Not Associatedwith A Trusted SQL Server Connection.(28000,18452)

Dec 12, 2007

Can anyone give a quick description of the meaning of this message andwhat needs to be done to get a connection.I'm running DBArtisan with SQLServer 2000 client SP4 installed.I also get the same message with MS Enterprise Manager so this iscoming out of the actual ODBC connection attempt.Thanks in advance!

View 1 Replies View Related

Login Failed Using SQL Server Login For Assigned Script Componet Connection String

Oct 14, 2007



Hi,

I have a script component. What it does, it queries the a table using a connectionstring assigned to it in the Connection Managers Editor (which is an ado.net adapter). this works fine when i'm using a windows login in the ado.net connection manager. But when i changed my connection to use SQL server login, I encounter this error:



OnError,,,Add new records to Dim_T_Status (Case),,,10/14/2007 5:54:47 PM,10/14/2007 5:54:47 PM,-1073450910,0x,System.Data.SqlClient.SqlException: Login failed for user 'CS_REPORT'.
at Microsoft.SqlServer.Dts.Pipeline.ScriptComponentHost.HandleUserException(Exception e)
at Microsoft.SqlServer.Dts.Pipeline.ScriptComponentHost.ProcessInput(Int32 inputID, PipelineBuffer buffer)
at Microsoft.SqlServer.Dts.Pipeline.ManagedComponentHost.HostProcessInput(IDTSManagedComponentWrapper90 wrapper, Int32 inputID, IDTSBuffer90 pDTSBuffer, IntPtr bufferWirePacket)
OnError,,,LOAD AND UPDATE OCEAN Dimension Tables,,,10/14/2007 5:54:47 PM,10/14/2007 5:54:47 PM,-1073450910,0x,System.Data.SqlClient.SqlException: Login failed for user 'CS_REPORT'.
at Microsoft.SqlServer.Dts.Pipeline.ScriptComponentHost.HandleUserException(Exception e)
at Microsoft.SqlServer.Dts.Pipeline.ScriptComponentHost.ProcessInput(Int32 inputID, PipelineBuffer buffer)
at Microsoft.SqlServer.Dts.Pipeline.ManagedComponentHost.HostProcessInput(IDTSManagedComponentWrapper90 wrapper, Int32 inputID, IDTSBuffer90 pDTSBuffer, IntPtr bufferWirePacket)
OnError,,,LoadOCEANDimensions,,,10/14/2007 5:54:47 PM,10/14/2007 5:54:47 PM,-1073450910,0x,System.Data.SqlClient.SqlException: Login failed for user 'CS_REPORT'.
at Microsoft.SqlServer.Dts.Pipeline.ScriptComponentHost.HandleUserException(Exception e)
at Microsoft.SqlServer.Dts.Pipeline.ScriptComponentHost.ProcessInput(Int32 inputID, PipelineBuffer buffer)
at Microsoft.SqlServer.Dts.Pipeline.ManagedComponentHost.HostProcessInput(IDTSManagedComponentWrapper90 wrapper, Int32 inputID, IDTSBuffer90 pDTSBuffer, IntPtr bufferWirePacket)

How to go about this?

cherriesh

View 3 Replies View Related

Dynamic Changes Of AS Connection Manager Failed

Feb 15, 2007

Hi,

in my actual szenario I have to change the Server (Connection String) of Analysis Services Connection Manager from my testserver SERVER1 to my production server SERVER2. Nearly everything is easy...I set a variable to the correct servername and I used a expression to change the connection string of the connection manager during run-time. I used this technic serveral time with ole db and it works fine.

Debugging of the project shows that the variable is set correctly. The delay validation flag is set to true. When I run the package the connection establish a connection to the server which I use due designtime.

Does anybody have an idea how I can fix it?

Regards
Klaus Hoeltgen

View 2 Replies View Related

The Connection Type OLEDB Specified For Connection Manager Is Not Recognized As A Valid Connection Manager Type - Why?

Mar 17, 2008

Greetings,

I have an SSIS package that I need to modify. It was developed in Visual Studio 2005 and runs faithfully in production on SQL Server 2005. Suddenly, I can't open the package on my own workstation. I see a big red "X" image and a message stating "Microsoft Visual Studio is unable to load this document." The real reason the document can't be loaded appears to be:

Error loading DataWarehouseLoader.dtsx: The connection type "OLEDB" specified for connection manager "Warehouse Logging OLE DB" is not recognized as a valid connection manager type. This error is returned when an attempt is made to create a connection manager for an unknown connection type. Check the spelling in the connection type name.


Does anyone know what causes this and what I can do? The package has been in production for 9 months and I've never seen this problem before.

Thanks,
BCB

View 10 Replies View Related

Connection Could Not Be Made, Login Failed For Use

Mar 18, 2006

I have sql server 2000 Personal Edition with service pack 4 loaded on a laptop running Windows XP and I'm trying to install a program that automatically loads all the tables and files to the SQL Server.

I keep getting the following error:

Your connection could not be created. Check your settings. The error was: Login failed for user "FileArch"

The program had been previously loaded on this laptop and I had to rebuild the hard drive. When I check Enterprise manager I see in Databases that the FileArch database is in Master as opposed to its own database.

The database missing is called FileArch.

If anyone can provide me with help to solve this I'd be grateful as a new member.

Bob

View 7 Replies View Related

AcquireConnection Method Call To The Connection Manager Failed

Feb 13, 2008

Hi All,
I have a DB2 database on aix server. we had to move some tables to SQL Server 2005. We created individual SSIS files for each table and saved it on the desktop. When I run the package file by double clicking on it the "Execute Package Utility" dialogue box appears and I can click on the "Execute" button and everything goes fine.
But if I try to open the same package using "SQL Server Business Intelligence Devlopment Studio" or to run the same package with DTEXEC /f <Filename> , it gives me below error.
=====================================================================================
Error: SSIS Error Code DTS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER. The AcquireConnection method call to the connection manager "SourceConnectionOLEDB" failed with error code 0xC0202009. There may be error messages posted before this with more information on why the AcquireConnection method call failed.
=====================================================================================


I am stuck on this error and need help!!!

Shailesh

View 1 Replies View Related

Error: The Connection Manager Failed To Defect From The Transaction.

Aug 3, 2007



Does anybody know what it means?
The context is: a package with a single Data Flow finishes with this error: [Connection manager "xxx"] Error: The connection manager failed to defect from the transaction.
All components inside the data flow reports a successfull green status, however the DataFlow Task remains yellow for a long time, when suddenly the package stops with the above message. Another information is that the table remains locked during package execution (a select on that table does not complete...). This is a serious issue, and I couldnt find any relevant information about that. Thanks in advance.



View 4 Replies View Related

Login Failed - Not Associated With A Trusted SQL Server Connection

Aug 25, 2006

I'm getting the following error:  login failed for user '(null)', Reason: Not associated with a trusted SQL Server connection.Here's my connection string : <add key="ConnectionString" value="Persist Security Info=True; Trusted_Connection=Yes; Integrated Security=SSPI; Application Name=CCMIS; Initial Catalog=CCMIS; Data Source=NameofServer; Network library=dbmssocn; Packet Size=4096;" /> I'm running a windows application that calls a web service to update a SQL database.  The application is using a windows group account and the between the web service & the SQL server it's using a domain account.  My user-id is a member of the windows group account.  I'm not sure of the relationship between the domain account and the group account or if there is one?  I'm new to this permissions stuff.  The DBA tells me nothing has changed on the SQL side and I haven't done anything to the application (which was working yesterday).  Any ideas?  

View 1 Replies View Related

SQL Server Login Failed - Not A Trusted Connection

Jan 21, 2004

I am trying to login to my SQL Server database using this:

conParks = New SqlConnection("Server=localhost;uid=Brian;pwd=abccba;database=Test")
conParks.Open()

The error I get is

Login failed for user 'Brian. Reason: Not associated with a trusted SQL Server connection.

Anyone know what I must change?

Thanks,

BB

View 3 Replies View Related

Login For User Sa Failed -- Not A Trusted Connection

Jun 24, 2007

I have 2 (XP Pro) machines -- each with its own instance of 2005 Express. I wrote a simple test in C# to access a few global vars such as @@VERSION.



When I run the test on 1 machine it works fine, but on the other machine it fails with the message: login failed for user sa, not a trusted connection. Both instances of Express have mixed mode authentication enabled & remote connections enabled.



If I add Integrated Security=true to the connection string, the test works on both machines. I believe this forces the connection to authenticate using Windows instead of SQL Server.



I have created a new user & password in Express, but the results are the same: 1 machine works & 1 fails.



The machine that fails is missing the following from the list of logins:

AIRSTREAMSQLServer2005MSFTEUser$AIRSTREAM$SQLEXPRESS



In fact, after poking around, I can see the problem with just the 2005 Management Console. Cannot access the 1 machine with SQL authentication using either of 2 users -- just in case I got 1 wrong.



Any help will be appreciated. I've run out of any good ideas.



TIA,

Joe







View 6 Replies View Related

Acquire Connection Execution

May 31, 2006



In the custome source Component

At the Runtime execution, Accquire Connection is getting called 3 times, why does that happen so many times, is there any way possible to restrict it to once?

thanks in advance

View 1 Replies View Related

SSIS - AcquireConnection Method Call To The Connection Manager Failed

Aug 30, 2006

Hi all,

I am facing a problem with the connection method, it says,

"[Store [10069]] Error: The AcquireConnection method call to the connection manager "Data Source Destination" failed with error code 0xC001A004. "

(Store - Look up component.)

This problem occurs only when i am using Transaction option, all the component(Look up,Destination etc) says the same error message in the Pre-Execute phase. But i can open the component and can able to see the data in preview.

And also this is not occuring in our testing environment. We have copied the same pakages in our production, the package failed stating the above. I can not simulate the same problem in my testing server.

Has anyone faced this kind of problem? please help me to solve this.

Thanks.

-Swarna.

View 17 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved